How to use Elke Aircon Stop Leak

Preventive Verification Test

  1. Identify the charge valve on the low pressure side of the refrigeration or air conditioning system and unscrew the cap.
  2. Connect a charging station and make the vacuum of the A/C system for at least 8 minutes.
  3. Check the value obtained with a pressure gauge.
  4. Switch off the charging station and check that the value obtained is maintained for at least 5 minutes.
  5. If it isn’t possible to respect this parameter it means that the leak is too big to be repaired.

Instructions for use

  1. Make the vacuum of the A/C system
  2. Connect the leak stop to the charge valve on the low pressure side of the A/C system and introduce the sealant
    PLEASE NOTE: if you use an exible adapter let the air inside the hose out, before connecting it to the system
  3. Disconnect from the A/C system
  4. Recharge the system following the manufacturer’s instructions
  5. Let the system work for at least 30 minutes to allow the leak stop to work